Overview of standard Drum Motors: 80i – 113i – 138i – 165i – 217i

        80i       113i       138i       165i       217i
      Diameter       81.5 mm       113.5 mm       138.0 mm       164.0 mm       217.5 mm
      Gear material       Steel       Steel       Steel       Steel       Steel
      Rated power       0.033 to 0.120 kW       0.058 to 0.370 kW            0.074 to 1.000 kW            0.306 to 2.200 kW            0.306 to 3.000 kW     
      Rated torque       2.3 to 26.8 Nm       7.4 to 86.4 Nm       14.7 to 174.4 Nm       28.1 to 365.2 Nm       28.1 to 533.6 Nm
      Belt pull*       58 to 657 N       132 to 1,522 N       216 to 2,527 N       347 to 4453 N       261 to 4907 N
      Velocity of the shell*             0.100 to 0.980 m/s            0.048 to 1.515 m/s       0.041 to 2.005 m/s       0.084 to 2.527 m/s       0.126 to 3.344 m/s
      Shell length SL       193 to 1093 mm            250 to 1400 mm       300 to 1600 mm       400 to 1750 mm       400 to 1750 mm
      Friction drive belt       Yes       Yes       Yes       Yes       Yes
      Positive drive belt       Yes       Yes       Yes       Yes       Yes
      Without belt       Yes       Yes       Yes       Yes       Yes

 

INTERROLL DRUM MOTOR 80I

  • Salt-water-resistant aluminium bearing housings
  • 3-phase AC induction motor
  • Dual voltage
  • Integral motor protection
  • Steel-hardened helical spur gear
  • Low noise
  • Maintenance-free
  • Lifetime lubrication
  • Reversible
  • Reinforced shaft for SL above 543 mm

Motor data

  • Motor type - Asynchronous squirrel cage motor, IEC 34 (VDE 0530)
  • Insulation class of motor windings - Class F, IEC 34 (VDE 0530)
  • Voltage - 230/400 V ±5% (IEC 34/38) (Most of the internationally common voltages and frequencies are available upon request)
  • Frequency - 50 Hz
  • Shaft seal, internal - Double-lipped, NBR
  • Protection rate - IP66
  • Thermal protection - Bi-metal switch
  • Operating mode - S1
  • Ambient temperature, 3-phase-motor - +5 to +40 °C
  • Ambient temperature for step-down motors - +5 to +25 °C
  • Rated power, 3-phase-motor - 0.033 to 0.120 kW
  • Rated speed, 3-phase-motor - 0.100 to 0.980 m/s
  • Rated torque, 3-phase-motor - 2.3 to 26.8 Nm
  • Max. tube length SL - 1,093 mm

 

Interroll Drum Motor 113i

  • Salt-water-resistant aluminium bearing housings
  • 3-phase AC induction motor
  • Dual voltage
  • Integral motor protection
  • Steel-hardened helical spur gear
  • Low noise
  • Maintenance-free
  • Lifetime lubrication
  • Reversible
  • Reinforced shaft for SL above 850 mm

Motor data    

  • Motor type - Asynchronous squirrel cage motor, IEC 34 (VDE 0530)
  • Insulation class of motor windings - Class F, IEC 34 (VDE 0530)
  • Voltage - 230/400 V ±5% (IEC 34/38) (Most of the internationally common voltages and frequencies are available upon request)
  • Frequency - 50 Hz
  • Shaft seal, internal - Double-lipped, NBR
  • Protection rate - IP66   
  • Thermal protection - Bi-metal switch
  • Operating mode - S1
  • Ambient temperature, 3-phase-motor - +5 to +40 °C    
  • Ambient temperature for step-down motors - +5 to +25 °C    
  • Rated power, 3-phase-motor - 0.058 to 0.370 kW    
  • Rated speed, 3-phase-motor - 0.048 to 1.515 m/s   
  • Rated torque, 3-phase-motor - 7.4 to 86.4 Nm   
  • Max. tube length SL - 1,400 mm

 

Interroll Drum Motor 138i

  • Salt-water-resistant aluminium bearing housings
  • 3-phase AC induction motor
  • Dual voltage
  • Integral motor protection
  • Steel-hardened helical spur gear
  • Low noise
  • Maintenance-free
  • Lifetime lubrication
  • Reversible
  • Reinforced shaft for SL above 900 mm

Motor data

  • Motor type - Asynchronous squirrel cage motor, IEC 34 (VDE 0530)
  • Insulation class of motor windings - Class F, IEC 34 (VDE 0530)
  • Voltage - 230/400 V ±5% (IEC 34/38) (Most of the internationally common voltages and frequencies are available upon request)
  • Frequency - 50 Hz
  • Shaft seal, internal - Double-lipped, NBR
  • Protection rate - IP66
  • Thermal protection - Bi-metal switch
  • Operating mode - S1
  • Ambient temperature, 3-phase-motor - +5 to +40 °C
  • Ambient temperature for step-down motors - +5 to +25 °C
  • Rated power, 3-phase-motor - 0.074 to 1.000 kW
  • Rated speed, 3-phase-motor - 0.041 to 2.005 m/s
  • Rated torque, 3-phase-motor - 17.8 to 174.4 Nm
  • Max. tube length SL - 1,600 mm

 

Interroll Drum Motor 165i

  • Salt-water-resistant aluminium bearing housings
  • 3-phase AC induction motor
  • Dual voltage
  • Integral motor protection
  • Steel-hardened helical spur gear
  • Low noise
  • Maintenance-free
  • Lifetime lubrication
  • Reversible
  • Reinforced shaft for SL above 1000 mm

Motor data

  • Motor type - Asynchronous squirrel cage motor, IEC 34 (VDE 0530)
  • Insulation class of motor windings - Class F, IEC 34 (VDE 0530)
  • Voltage - 230/400 V ±5% (IEC 34/38) (Most of the internationally common voltages and frequencies are available upon request)
  • Frequency - 50 Hz
  • Shaft seal, internal - Double-lipped, NBR
  • Protection rate - IP66
  • Thermal protection - Bi-metal switch
  • Operating mode - S1
  • Ambient temperature, 3-phase-motor - +5 to +40 °C
  • Ambient temperature for step-down motors - +5 to +25 °C
  • Rated power, 3-phase-motor - 0.306 to 2.200 kW
  • Rated speed, 3-phase-motor - 0.084 to 2.527 m/s
  • Rated torque, 3-phase-motor - 28.1 to 365.2 Nm
  • Max. tube length SL - 1,750 mm

 

Interroll Drum Motor 217i

  • Salt-water-resistant aluminium bearing housings
  • 3-phase AC induction motor
  • Dual voltage
  • Integral motor protection
  • Steel-hardened helical spur gear
  • Low noise
  • Maintenance-free
  • Lifetime lubrication
  • Reversible
  • Reinforced shaft for SL above 1200 mm

Motor data

  • Motor type - Asynchronous squirrel cage motor, IEC 34 (VDE 0530)
  • Insulation class of motor windings - Class F, IEC 34 (VDE 0530)
  • Voltage - 230/400 V ±5% (IEC 34/38) (Most of the internationally common voltages and frequencies are available upon request)
  • Frequency - 50 Hz
  • Shaft seal, internal - Double-lipped, NBR
  • Protection rate - IP66
  • Thermal protection - Bi-metal switch
  • Operating mode - S1
  • Ambient temperature, 3-phase-motor - +5 to +40 °C
  • Ambient temperature for step-down motors - +5 to +25 °C
  • Rated power, 3-phase-motor - 0.306 to 3.000 kW
  • Rated speed, 3-phase-motor - 0.126 to 3.344 m/s
  • Rated torque, 3-phase-motor - 28.1 to 533.6 Nm
  • Max. tube length SL - 1,750 mm

Call us on:

+44 (0)28 867 62295